rx on falcon ma lock

RELATED FAQS

Question
Answer
The Von Duprin 6210 electric strike was designed for retrofit applications and will not work with the Falcon MA series lock when strike and lock body are mounted at standard locations (centerline o...
The MA lock does not have Vandlgard or a breakaway trim feature, however, the lever spindle on the MA lock will shear if too much force is applied in order to prevent internal lock damage and resis...
The thumbturn will work but the spindles sit 90 degrees off from each other (Schlage is square, Falcon is diamond).  The result is the throw will end up 10 and 2 o'clock instead of 12 and 3. 
Here are some of the major differences between the M and MA-Series.  Lever mounting post holes -  Locations have changed on door template.  (12 and 6 o'clock for M lock, MA lock is approx 1 and...
Falcon began offering an RX switch with its electrified functions beginning January 17th 2012.  To specify, add "RX" to the end of the part number. Example:  Storeroom Function, Fail Safe (EL), 12...
The MA RX features independent switches within the chassis that allow the customer to choose whether to monitor the inside or outside knob/lever.
Each switch is pre-wired to work with either normally open or normally closed systems, with color coded 5 ft long leads.
See Marketing announcement here
Solenoid: Black (2 wires) Case side RX Normally Open: Green Normally Closed: Orange Cover side RX Normally Open: Gray Normally Closed: Red Common: Yellow
Refer to the MA RX diagram here for more information.
No parts are compatible between the Falcon MA-Series and the obsolete Falcon M-Series.
The MA was launched 4/1/10 and replaced the Falcon M lock. Newer Marketing Bulletin added on 4/26/2010 (Some items not yet available!!)