Question
Answer
What are the Von Duprin part numbers for RX, LX and RX,LX-LC switch kits for field installation?
Resolution:
The attached table shows the part numbers for LX-RX and LX-RX-LC switches field installed.:
Why does the AD300-993 and AD400-993 require Von Duprin RX-LC switch
Resolution:
Here is detailed information on why the Von Duprin RX-LC Swtich is required by the AD300 and AD400 993 units. A low current switch is needed because … - &nb...:
What is the difference between an RX switch and an RX-LC (low current) switch?
Resolution:
The standard Von Duprin switches (RX and LX switches in exit devices, and DS dual switches in 6100 and 6200 Electric Strikes) are rated for 0.05A to 2A @ 24 VDC. The low curren...:
Can a pneumatic (PN) 33A/35A/98/99 exit device use the RX or LX switches?
Resolution:
PN33/35/98/99 Pneumatic exit devices are not usually used with RX or LX switches since the Pneumatic PN device is used instead EL to eliminate the electric from the device.:
Is there a template that shows where to drill the hole for E/EL/SS/RX/LX/CX wires?
Resolution:
The hole should be drilled in the field once the end cap is located on the door. It is a 5/8" hole, that is located 5/16" from the end of the mechanism case. See installation instruction of t...:
What is the difference between Von Duprin LX and/or RX switches and the Signal Switch SS option?
Resolution:
The RX monitors the push bar while the LX monitors the latch bolt of the exit device. A SS device has an LX and a key cylinder switch plus an emergency push bar signage.:
Can you add the LX option to a Von Duprin device that already has the RX option?
Resolution:
The Von Duprin RXLX combination switch must be ordered together as one assembly. Existing RX or LX switch must be removed to install the combination RX LX switch. Make sure correct RX LX combinatio...: