rim panic mounting height

RELATED FAQS

Question
Answer
Von Duprin 6300 electric strike will operate with 88 rim but not 88F fire rated exit devices.
RPD; Panic Exit
The existing 373L control was modified and re-named as 379L to allow us to use the 55 rim device on an ADA door opening.  The 379L control is our 373L with different hex st...
Position the 379L  trim and attach with countersunk screw into the bottom stud of the trim.  Position the 55 Rim device and attach with the device mounting screw through the head of th...
The ANSI 156.19 standard states (in appendix A-5 Knowing Act Switches) that wall actuators are to have an installation height of a minimum of 34" and a maximum of 48" (center of the switch) of...
According to ANSI specifications for cylindrical or mortise locks: The lock strike centerline should be 40 5/16" from the bottom of the frame with the lock in relation to the strike. &...
Panic devices are not designed for exterior application. As with any mechanical device, exposure to the elements may affect the operation and life of the device and/or finish and may void&n...
Water and electricity do not mix.  Von Duprin electrified devices can NOT be used in an exterior environment.