What is the backset for a 98/99 rim device with a 1609 strike?
Resolution:
The backset for a 98/99 rim PANIC device with 1609 strike is 2 3/8" from center of the opening to center line of the device. See template
What strike is used for a pair of doors with a Dor O Matic Rim device x Flushbolts on inactive door?
Resolution:
The STK45 strike is used on the inactive door leaf.
Is the Von Duprin 1609 strike fire rated for pairs of doors?
Resolution:
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F,...
What strike do I use with a Von Duprin rim device on a pair of doors with flush bolts?
Resolution:
NON Fire Rated doors would use the 1609 strike applied to the inactive leaf with flushbolts. This may NOT be used on Fire Rated openings.
Which strike do you use with an XP98/99 device?
Resolution:
The 909 strike is used in single and paired non-fire rated and single fire rated openings. The 954 strike is used in fire rated paired openings.
Resolution:
The 1609 strike cannot be used with Von Duprin XP98/99 exit device.