return spring mortise lock

RELATED FAQS

Question
Answer
Falcon is reintroducing the lever return spring for the discontinued Falcon M mortise series.  Effective November 1, 2014 the lever return spring is now available for purchase with a list pric...
Issue: One or both levers don't stay horizontal and droop down.Facts: Falcon T series locks in a high use application.Cause: Weak or broken springs within the springcage.Solution: Replacement sprin...
See Falcon MA lever assembly below: The spring mechanism (E) returns the lever to horizontal.  The parts are not sold separate, so if the lever sags, the entire lever assembly shoul...
Lever assemblies part numbers are found in the Pricebook.  Note they are handed.
Only the lever return spring is available.
Related solution: What is the part number for the lever return spring for the old M series mortise lock?
The springcage part number is L283-040.
These parts are no longer available.  For reference the spring part number is 4841 and the clip part number is 4326.
The Schlage L-Series mortise lock spindle and spring part number can be found in the Table 1.     Spindles and Springs   Part Number  Description  L283-060 Spindle and spring, 1...
With the new FW package 2.19.0; AD300 FW 2.17.0 and AD400 FW 2.17.0 (released 09/23/2011) the firmware looks for a motor clutch switch change after a motor move command. If there is no motor clutch...
If the triangles in the spring cage spindle are not aligned properly the motor will not move enough to change the clutch switch. Is is very likely with a lock on the bench; but a properly install...
When the new firmware moves the motor three times without seeing the clutch switch change it reports to the SUS diagnostics that the motor is stalled. Aligning the triangles will let the motor move...
If the lock is mounted on the door, it is necessary to adjust the mortis/cylinder tightness and spring cage tailpiece alignments, making sure there is no binding or stopping of the spring...
Just align the triangles per the installation instructions to allow full motor movement.   - This will eliminate the SUS motor STALL report. - This will eliminate the three ...