Standard and Full Size I/C mortise cylinders on the L9485 and L9486, Hotel or Restroom Locks, use the concept of a ward ring to lock out all change keys once the deadbolt is thrown. Instead of a fu...
HANDINGA stop ring is installed on the right side for right hand operation and on the left side for left hand operation.  Right hand shown below.
L9485:  Latchbolt retracted by key outside or by knob/lever inside. Outside knob/lever always fixed. Deadbolt thrown or retracted by inside thumbturn.  When deadbolt is thrown, all keys become ino...
Apartment Corridor Lock function is defined as a lock where the latch bolt operated by lever from either side, except when outside lever is made inoperative by a stop or mechanical means other than...
Schlage offers a High, Medium, and Low risk HSLR ligature Resistant trim offering for the L9000 and ND locks, Data Sheet.Schlage offers a Low to Medium Risk SL1/SK1 ligature resistant trim for...
High Risk Areas*Patient bedroomIn-suite bathroomIn-suite closetTime-out roomPatient difficult to manage; or risk of solitary and/or unsupervised areas.Medium risk areas*Living roomDining roomGroup ...
The lever removal tool can be used to remove levers in both the ND and the L Series mortise locks.
On August 15, 2012 Schlage began shipping a new, more ergonomic, lever removal tool to coincide with Phase 1 of the ND-Series improvement project.  This tool can be used for Schlage ND-Series ...
Installers have reported that their AD-CO Series cylindrical or mortise locks will unlock whenever the outside lever is lifted.    This will occur if the outside spindle (square post) is install...