Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
removable mullion and strike options
”
RELATED FAQS
Question
Answer
Von Duprin electrified mullions and handing details.
Resolution:
4754, 4854 and the 9854 are electrified mullions and handed as noted below: 4754 is not handed: Prepared for two 4263 monitor strikes. Use with all Von Duprin rim panic devices 4854 is han...:
What mortise cylinder cam is needed for KR4023?
Resolution:
The KR4023 mullion requires a 1-1/4" mortise cylinder with straight cam. This is stated in box 7 on the first page of the KR4023 mullion instructions.:
Which keyed removable kit is used with a 4754, 4854, 9854, or 9954 mullion?
Resolution:
The Von Duprin 4754, 4854, 9954, and 9854 mullions can be converted or ordered with key removable option. KR54-F kit is the conversion kit to convert the above mullions to key removable mullion.:
Do the electric removable mullions come with a quick connector?
Resolution:
The Von Duprin electrified steel mullions, 4854 and 9854 come with a quick connector that connects the electric strike wires from the mullion to the frame through the top fitting. ...:
What cylinder do I use on a Von Duprin Keyed Removable Mullion?
Resolution:
see installations instructions here :
REMOVABLE MULLION
Resolution:
TSF, closed section; Hardware Mullion:
Does Steelcraft offer a KD (knocked down) assembly for sidelight frames?
Resolution:
Side Light and Side Panel frames - Side Light and Side Panel frames are not KD (Knock Down), they must be assembled and welded. All side lite and side panel frames must be assembled and welde...:
Is the keyed removable option KR available on Von Duprin aluminum mullions?
Resolution:
Key removable option is not available for any of Von Duprin aluminum mullions.:
What is the backset for a 98/99 rim device with a 1609 strike?
Resolution:
The backset for a 98/99 rim PANIC device with 1609 strike is 2 3/8" from center of the opening to center line of the device. See template :
Can the Von Duprin 5100 electric strike be used on a pair of doors?
Resolution:
The following application information apply to the 5100 electric strike: Can only be used on a single door with a cylindrical lock Can not be used on a pair of doors Can not be used on a mullion:
How can the Von Duprin 4854 mullion be ordered when using the 6300 electric strike?
Resolution:
:
Can the 4854 mullion be ordered as prepped for two 6111 electric strikes?
Resolution:
There is not enough room to install two 6111 electric strikes back to back in 4854 mullion.:
What strike would be used for a 25-R for pair without mullion?
Resolution:
For non fire rated doors only the 1609 strike would be used on the inactive leaf that is flush/surface bolted or with a *surface or concealed vertical rod device on other door leaf.:
What electric strikes can be used with the Von Duprin aluminum mullions?
Resolution:
Aluminum mullions 5654 or 5754 are not designed to accept any electric strike including 6300 surface mounted electric strike.:
What mullions should be used with XP devices?
Resolution:
The Von Duprin XP98/99 device uses a different strike than standard 98/99 device. The 909 strike is for non fire rated XP devices and the 954 strike is for the fire rated XP device. 49/9954 mul...:
How do I order a Von Duprin mullion prepped for something other than our standard strikes?
Resolution:
To use Von Duprin mullion for something other than our standard strike, order the mullion "Blank" and prep in the field.:
What strike do I use with a pair of 22 rim device without a mullion?
Resolution:
The 1609 strike can be used on an inactive door with 22 rim device. NON-FIRE RATED doors only. :
FRAME ELEMENTS
Resolution:
Head, Jamb, Hinge Jamb, Strike Jamb, Blank Jamb, Mullion, Open sSection, Closed Section; frame componets:
What is the minimum door width for a 98/99 Rim device with 4954 mullion?
Resolution:
Minimum door opening for a 98/99 rim device with a 4954 mullion and 299 strike is 26.687" (26 11/16"):
Why does the auto operator not open the door when installed with a Chexit?
Resolution:
Chexits are NOT electric latch retraction devices, therefore the latch will not retract and allow the opener to swing the door open. Chexits block and unblock the latch. In order for a Ch...: