QEL Kit instructions

RELATED FAQS

Question
Answer
Kits are available per the following criteria.    Product Bulletin Required Series 94 or 95 Fire or Panic 3FT/4FT or 2 ft 6 in / 2 ft 10 in Finish  Optional LX...
See below for part numbers:  114317-00 QELA Mod. Conv. Kit 040061-00 QELA Mod. Conv. Kit w/Connectors 958002-00 HD-QELA Mod. Conv. Kit 040062-00 HD-QELA M...
The Von Duprin EL33A/35A/98/99 device can be converted to the QEL device by getting the correct sized QEL baseplate conversion kit. The existing PS914 or PS873 power supply can be used. ...
The QEL conversion kit (3' or 4') and the RX switch kit (050251-00) can convert the 9927 to QEL-RX9927 device.
To keep the Von Duprin electric latch retraction EL or QELA exit device dogged (retracted) all day, have your access control, Key pad, key switch, fire alarm contact or any other signals ...
Calibration is an internal process of the QEL device when energized the 1st time.  The solenoid will pull and drop 3 times on a standard calibration.  Calibration can be forced by pr...
The new QEL motor has a label affixed to the cover, the older QEL motor has no such label.  See attached image.
We ship the standard installation instructions because it contains enough information to show how to convert the trim from mechanical to electrical.
There is currently an Exit Alarm Kit for the 19 device. It is ordered by description: 19 EAK 3' x Finish 19 HWEAK 3' x Finish (Hardwired version) 19 EAK 4' x Finish 19 HWEAK 4'' x F...
The part will be configured as CONVERT.XXXX part numbers. The customer need to specify the following criteria. Required:   Series 94 or 95, Fire or Panic , 3 feet/4feet or 2 feet 6 inches/2 feet...
The 900-2Q board is no longer available. For warranty purposes, QEL conversion kit and 900-2RS board are required. The 900-2RS replaces the 900-2Q board.
Followings are the list of the electric latch retraction EL/HDEL (hex dogging), QEL (quiet) kits: 114317-00 QELA Mod. Conv. Kit 040061-00 QELA Mod. Conv. Kit...
The Von Duprin RXLX combination switch must be ordered together as one assembly. Existing RX or LX switch must be removed to install the combination RX LX switch. Make sure correct RX LX combinatio...