Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
QEL Kit instructions
”
RELATED FAQS
Question
Answer
Is there a conversion kit to make 94/95 devices into a QEL?
Resolution:
Yes. Required Series 94 or 95 Fire or Panic 3FT/4FT or 2 ft 6 in / 2 ft 10 in Finish Optional LX switch &nbs...:
Does Von Duprin offer replacement QEL motors?
Resolution:
See below for part numbers: 114317-00 QELA Mod. Conv. Kit 040061-00 QELA Mod. Conv. Kit w/Connectors 958002-00 HD-QELA Mod. Conv. Kit 040062-00 HD-QELA M...:
Can you convert the EL33A/35A or EL98/99 series exit device to the QEL device?
Resolution:
The Von Duprin EL33A/35A/98/99 device can be converted to the QEL device by getting the correct sized QEL baseplate conversion kit. The existing PS914 or PS873 power supply can be used. ...:
Can QEL and RX be added to an existing 9927?
Resolution:
The QEL conversion kit (3' or 4') and the RX switch kit (050251-00) can convert the 9927 to QEL-RX9927 device.:
What is needed to keep the EL device retracted all day?
Resolution:
To keep the Von Duprin electric latch retraction EL or QELA exit device dogged (retracted) all day, have your access control, Key pad, key switch, fire alarm contact or any other signals ...:
How is the QEL calibrated?
Resolution:
The QELA motor that has shipped since 2015 is self calibrating. Older versions had a calibration button, and these notes would apply: Calibration is an internal process of the QEL device&...:
How do I identify the new QEL motor launched in 2012?
Resolution:
The new QEL motor has a label affixed to the cover, the older QEL motor has no such label. See attached image.:
Do we have conversion instructions for the E996 when shipping conversion kits?
Resolution:
We ship the standard installation instructions because it contains enough information to show how to convert the trim from mechanical to electrical.:
Is there an Exit Alarm Retrofit Kit (EAK) for the 19 series?
Resolution:
These kits for the 19 Series were discontinued June 11th, 2012 when the updated alarm kit for the 24/25 series was released. Prior to discontinuation, it was o...:
What is the part number for QEL94/95 inpact conversion kit?
Resolution:
The part will be configured as CONVERT.XXXX part numbers. The customer need to specify the following criteria. Required: Series 94 or 95, Fire or Panic , 3 feet/4feet or 2 feet 6 inches/2 feet...:
Will there be 900-2Q boards for warranty purposes now that the QEL'S do not require the boards?
Resolution:
The 900-2Q board is no longer available. For warranty purposes, QEL conversion kit and 900-2RS board are required. The 900-2RS replaces the 900-2Q board. :
Is there a Von Duprin conversion kit to change mechanical to electric latch retraction EL in the field?
Resolution:
Followings are the list of the electric latch retraction EL/HDEL (hex dogging), QEL (quiet) kits: 114317-00 QELA Mod. Conv. Kit 040061-00 QELA Mod. Conv. Kit...:
Can you add the LX option to a Von Duprin device that already has the RX option?
Resolution:
The Von Duprin RXLX combination switch must be ordered together as one assembly. Existing RX or LX switch must be removed to install the combination RX LX switch. Make sure correct RX LX combinatio...: