What is the minimum and maximum reveal for a 9500 Series Senior Swing operator?
Resolution:
The 9542, 9553, 9563 surface mounted Senior Swing with a regular arm, mounted on the push side of the door, can handle a reveal from 1 1/8" up to 10". The 9542, 9553, 9563 surface mounted Senior S...:
Where is the RA closer reinforcement located on a frame for a Regular Arm Closer?
Resolution:
Optional closer reinforcements are located at 3" from hinge jamb to the beginning of the reinforcement plate. This applies to Regular Arm, Parallel Arm, Top Jamb. Regular Arm (RA) closer reinfor...:
Can a 4040XPT DE be used with a 4" reveal on the pull side?
Resolution:
The LCN 4040XPT with a reveal deeper than 1/8" on the pull side of the opening requires a Double Egress (DE) arm.DE arms are handed arms and cannot have handing changed in field.ST3073 Standard 404...:
HINGE SIDE REVEAL
Resolution:
Track Style, Double Egress Mount:
What is the maximum size of a welded elevation frame?
Resolution:
The following size limitations per frame unit, are in enforced for welded elevation frames shipped from the factory. These limitations are in place due to the physical size of shipping tr...:
Does Steelcraft offer a KD (knocked down) assembly for sidelight frames?
Resolution:
Side Light and Side Panel frames - Side Light and Side Panel frames are not KD (Knock Down), they must be assembled and welded. All side lite and side panel frames must be assembled and welde...:
Will 1 7/16" thick glass require a special rabbet size on borrowed light frames?
Resolution:
Yes. 1 7/16" thick glass but a special rabbet size is required. The size of rabbet required for the frames would depend on the size of the glazing bead being used. For 1" wide glazing stops, ...:
Can louvers be installed in fire rated transom frames?
Resolution:
NO - Louvers are not approved for installation in a fire rated transom / side panel frames. NFPA Pamphlet 80 - paragraph # 6.3.4.4 states “Louvers shall not be installed in either transom or s...:
What is the maximum frame size for a label transom and sidelight frame?
Resolution:
Maximum hourly rating for a transom and side light or panel frame is 1 1/2 hour (90 minutes).In masonry wall application the maximum is 13'6" x 12'2"In stud wall application the maxi...: