push and go

RELATED FAQS

Question
Answer
The following may cause the ALK to go into alarm: Make sure red and blue wires on the RX switch are connected to the exit alarm ALK terminal block and yellow wire is taped off. Check the red an...
All Senior Swing models are heavy duty operators and have the Push-N-Go (PNG) feature.  This feature is a programmable function in the control module.  The PNG settings are: Off, On, or FD (fixed)...
The 4600 Series operator does not have a Push N Go feature. The LCN operators with a Push N Go feature are the Senior Swing, Benchmark, and the Falcon 8200 series.
power assist
Yes. These units can be converted by changing out the arm assembly everything else is the same. To convert a 8242 to a 8231, you need to replace the arm assembly. Order part # 8230-3077 PLCM, wh...
If the 9100 Series Benchmark operator does not open when the actuator is pushed: Verify the unit has 120 volts applied to it. Verify the the power light on the control box is on. If not, check ...
Pull Side Mount: The 4040SEL X ST-2966 is required for pull side mounting with swing clear hinges. ST-2966 template
Push Side Mount: Take the dimensions for the closer and track from centerline of swing clear hinge pin for the push side mount.
There is potential for ND40/ND44's manufactured around March 2011 to remain locked after egress, or after the latch is depressed.  There was an issue with the keycam that created a bind when l...