Answer
Does Ives offer a continuous hinge or pivot for lead lined doors?
Resolution:
Ives does not offer a continuous hinge designed specifically for lead lined doors. Standard hinges may work if the hinge and mounting hardware do not penetrate the lead lining in the door.&nb...:
Does the door prep need to be altered when ordering the L9000 locks lead lined?
Resolution:
The door template L1 states: "Lead Lining: When L9000-Series or L400-Series locks are ordered with lead lining, add 1/8" to the width of the mortise cut-out on the lock case cover side of installa...:
Why are lead lined frames used?
Resolution:
Lead lined frames are intended for use in the X-ray Room locations in Health Care facilities. Frames are provided by Steelcraft prepped as follows: Frames are supplied knock-down (KD). Fram...:
LEAD LINED FRAME
Resolution:
Radiation, Lead Lined:
Is lead lining a GJ overhead an option or even needed when used in an X-ray room?
Resolution:
Lead lining is not needed, since the channel or through bolt is solid and the x-rays will not penetrate the solid metal.:
What is the replacement for the Locknetics 9100 series electric strike?
Resolution:
The Locknetics 9100 series electric strikes are replaced with Von Duprin 6211 and 6210 electric strikes. The 6211 is used if the frame is being replaced. The 6210 is for ...: