prefix "PA" for exit devices

RELATED FAQS

Question
Answer
The use of a 62A Shoe (required) would be used to mount a 4040XP Parallel Arm  with a "SURFACE" GJ 70, 79, 81, 90, or 450 series stop. You would order the 4040XP with a Reg w/62A arm op...
To order Von Duprin exit devices,  reference the "How to order" section in the Von Duprin catalogs. All Von Duprin device series Catalogs are available on website. Choose  "Cata...
If device backset is correct, replacing the device center case & center case cover with a F-24-R to add deadlocking to the latchbolt.  Parts to the F-24R center case & cover can b...
The backset of the device may be too large and the latchbolt of the standard 24-R is "walking" into the center case caused by the back/forth motion of the door. Verify the device backset ...
If device backset is correct, replacing the device center case & center case cover with a F-24-R to add deadlocking to the latchbolt would resolve the issue. Parts to the F-24R center case...
The 6111 electric strike can be used only on non rated openings less bottom rod with pullman top latch (use ES prefix when ordering device). Device back set will change to match the centerline of t...
Not for use in fire rated openings.
Order the 25 device with the "HH" prefix as described in the device options in the Price Book.