Power Supplies by others

RELATED FAQS

Question
Answer
The Von Duprin PS914 power supply must be used on the EL devices with either the 900-2RS or 900-4RL option board since the EL devices requires power supplies set at 24VDC to be able to provide the ...
  You can use a Von Duprin PS914 power supply with any of the following option boards depending on the application. 900-2RS board  will power 1 or 2 devices that do not require timing from pow...
As of Feb. 23rd 2011 Falcon RDS-2 power supply has been discontinued and no longer available.
The older ELR 17/18 device would have to replaced with a new EL-24/25 device and use the PS914 with either the 900-2RS or 900-4RL board.
The Von Duprin PS873-2 power supply replaced the old Von Duprin PS871 power supply. The Von Duprin PS914-2RS power supply replaces the PS873-2 or PS871 power supply and is currently the supply r...
RX switch is request exit and LX switch is latch bolt monitor switch. They do not required a power supply directly. The electrified hardware that RX or LX switch conne...
MPB840 = PS914power supply, MPB842 = PS914-2RS power supply.