Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
parrallel arm door closer
”
RELATED FAQS
Question
Answer
What do I need to do to make my 4041 Reg/PA a hold open arm?
Resolution:
When placing an order for a 4041/4040XP Rw/PA with hold open, it would be ordered as a 4041 /4040XP Hw/PA. For an existing Rw/PA requiring the addition of a hold open function, a hold open arm woul...:
What is the difference between an LCN CUSH arm, and an LCN EDA arm?
Resolution:
EDA ARM - The EDA arm is a heavy duty parallel arm mount. The degree of door opening is determined by the template used for mounting. EDA arm closers can only be mounted as a Push Side parallel ar...:
Where is the RA closer reinforcement located on a frame for a Regular Arm Closer?
Resolution:
Optional closer reinforcements are located at 3" from hinge jamb to the beginning of the reinforcement plate. This applies to Regular Arm, Parallel Arm, Top Jamb. Regular Arm (RA) closer reinfor...:
In what direction should the hold open nut be pointing for a 4041 H closer, up or down?
Resolution:
Make sure that the hold open nut is not on upside down. The orientation of the hold open nut depends on the mounting. On a Top Jamb "Push Side" mount, the hold open nut would poi...:
Why does the arm of my 4110 EDA touch the door when it is closed?
Resolution:
If the closer arm is touching the door, it is because the arm or the closer body is not templated correctly. Confirm dimensions are taken from the proper location and make corrections if needed. :
Can I use a Glynn Johnson 410 with a 4040 regular (pull side) mount?
Resolution:
ST-1630 is required when mounting a 4041 or 4040XP door closer regular (pull/hinge) side with a concealed GJ100 or GJ410 series over head stop.:
What arm can I use for the old LCN 4030/4130 closer?
Resolution:
The old 4030/4130 closers and arms are obsolete, there is nothing to replace them. No arm from other closers will fit There is no closer that can replace the old 4030 series closer with the exa...:
Can you replace a regular arm with a hold open with out moving the door closer?
Resolution:
Yes, as long as you stay with the like style arm. Example: replace an RW/PA with HW/PA, replace an EDA with HEDA, or replace a CUSH with HCUSH.: