Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
parallel arm adapter
”
RELATED FAQS
Question
Answer
How can I make my regular arm closer mount parallel arm?
Resolution:
This can only be done with universal, non-handed closers: 1250, 1260, 1450, 1460, 4030, 4040XP, and 4050A.You would need an xxxx-62PA shoe to adapt from regular arm to parallel arm mount...:
Will a 4040 Hw/PA hold open at 180°?
Resolution:
The 4041 Rw/PA and the Hw/PA have the same template. The only difference is the arm. The 4041/4040XP Hw/PA, if mounted to the 180° template, will hold the door open at 180°. Rw/PA is Regular A...:
What are Pneumatic Automatic Operators?
Resolution:
Pneumatic Automatic Operators are used in areas where electrically operated devices are not convenient or permitted. Consists of a modified, heavy-duty door closer for manual oper...:
What is the difference between an LCN CUSH arm, and an LCN EDA arm?
Resolution:
EDA ARM - The EDA arm is a heavy duty parallel arm mount. The degree of door opening is determined by the template used for mounting. EDA arm closers can only be mounted as a Push Side parallel ar...:
Can a 4041 EDA be mounted top jamb?
Resolution:
The 40401/4040XP closer with optional EDA arm has to be mounted parallel arm on the push side of the door.:
What do I need to do to make my 4041 Reg/PA a hold open arm?
Resolution:
When placing an order for a 4041/4040XP Rw/PA with hold open, it would be ordered as a 4041 /4040XP Hw/PA. For an existing Rw/PA requiring the addition of a hold open function, a hold open arm woul...:
Where is the RA closer reinforcement located on a frame for a Regular Arm Closer?
Resolution:
Optional closer reinforcements are located at 3" from hinge jamb to the beginning of the reinforcement plate. This applies to Regular Arm, Parallel Arm, Top Jamb. Regular Arm (RA) closer reinfor...: