Question
Answer
How can I cover a 86 or 161 prepped door with a 19-R?
Resolution:
The 4170 cover plate can be used to cover the 86 & 161 prepped doors.:
Can I put an old style hex dogging kit (050153) on my 99 panic device?
Resolution:
We don't recommend to use the old style hex dogging kit into the new 98/99 exit device but it would fit as long as the device is not fire rated.:
How is a ELR or panic device wired to a Senior Swing?
Resolution:
EL devices are wired to the Senior Swing, using the P10 (761465) cable. Connect the "GRAY" wire to the SC terminal on the 900-2RS card in the Von Duprin Power Supply and the "VIOLET" wire to the ...:
What is the difference between Panic Hardware and Fire Exit Hardware?
Resolution:
The most obvious difference (in the device) is the lack of mechanical dogging on a Fire Rated Device. There are some internal parts that may be different and the method it is secured to the d...:
When are Panic Devices required?
Resolution:
The use of Panic Hardware and/or Fire Exit Hardware is required by the International Building Code (IBC) and NFPA 101 – The Life Safety Code, depending on which code and which edition of the code i...:
Can the 8200 power an EL panic device?
Resolution:
The 8200 can not supply the power needed on an EL dev ice. The EL device requires a Von Duprin PS914-2RS or PS914-4RL power supply or the older Von Duprin PS873-2 or PS873-4TD models.:
What is the part number for the Von Duprin maintenance kit?
Resolution:
Von Duprin has a maintenance kit part number 050046-00 and maintenance instruction, part number 941079-00 for 98/99 series devices. There are some common parts between 98/99 series and 22...:
Are there any instructions for Von Duprin device maintenance?
Resolution:
Please see the Maintenance Kit Manual for information on device lubrication as well as complete breakdowns and parts lists for Von Duprin exit devices.Exit devices and latc...:
Does Von Duprin have an exit device that is pneumatic?
Resolution:
The Von Duprin Pneumatic or "PN" device does not have a specific listing or certification pertaining to hazardous locations.: