overhead stop on pairs

RELATED FAQS

Question
Answer
Clear Opening Width for swinging doors is measured (with the door open 90 degree) from the face of door to stop soffit on strike jamb.          &nbs...
A special template is not needed, the closer drops down far enough on the door where it does not conflict with the GJ100 series concealed overhead stop. 
A 4040-18G drop plate will be needed to drop the closer and arm down far enough not to conflict with the GJ 90 series overhead stop.
Special template ST-2211 is used to mount a 2030 series closer with a GJ 70,79,81,90, and 450 series overhead stops. This ST works with any GJ "surface" mounted stop. The 2030 closer cannot b...
The LCN 4041/4040XP and the Glynn Johnson 90 series can be mounted in conjunction with each other without a special template.  The 4040 door closer is on the pull side of the door and the GJ 90 is ...
It would be unnecessary to use the CNS/Cush arm and the Glynn Johnson overhead devices in the same application, both mechanisms stop the door.