occupied indicator with key

RELATED FAQS

Question
Answer
The 09-611 indicator stands off the door 0.39".
The pricebook suggests (for a 1-3/4" door) using a 1-3/8" cylinder when installing with an 09-611 occupancy indicator.
The L496 is a Small mortise deadbolt lock:Deadbolt lock with "occupied" indicator - Deadbolt is operated by key outside or thumbturn inside. Furnished with 09-611 per L583-375 indicator. When ...
The ND40 does not have this option.  You will need to look at a mortise lock, L9496, or a deadbolt such as the B571.
This change was implemented in firmware package CO.A.6 (or later) to help the customer in the communication and coupling process between the CO200 (CO250) and the hand held device (HHD). ...
The green LED is to be lit up until the spindle (Triangles and Key Switch) are aligned properly; providing a visual indication of the problem.  
If the mechanical alignment of the triangles on the back of the outside escutcheon are not aligned, the CO200 or CO250 will not connect with the SUS/HHD and will appear to be unresponsive...
In firmware CO.A.6 (or later) the Schlage button on the CO200 (CO250) will turn green anytime that the spindle triangles on the front escutcheon are out of alignment or the mechanical key switch is...
When unlocking the CO200 door by mechanical key override, the green led will be continuously ON until the key is released. This will occur after firmware CO.A.6 (or later) has been installed int...
L9496 is a Privacy mortise lock with “Occupied” Indicator. Knob/lever retracts latchbolt from either side. Deadbolt thrown or retracted by key outside (retraction by key required in the event ...
Privacy lock with "Occupied" indicator - Latchbolt is operated by knob/lever on either side. Deadbolt is thrown or retracted by key outside (retraction by key required in the event of an emergency)...
DISCONTINUED LATE 2014The L583-375 was used when ordering a L-Series lock with an indicator or the indicator rose/escutcheon separate to designate an indicator that reads "OCCUPIED" ...