Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
nl-op instalation manual
”
RELATED FAQS
Question
Answer
Can the 88 device be ordered as NL-OP?
Resolution:
You would have to order the device as 88NL less trim, the device will be shipped as an 88EO. The EO device has the proper backplate equipped with an NL cam to accept a rim cylinder ...:
How to order a 25-C device with the NL-OP trim function?
Resolution:
Device would be ordered as a 25C-C as of June 2012.The C-C suffix designates the 25C will come with the 718C-C cylinder control which uses a 1-¼" mortise with a narrow straight cam:
Does Von Duprin offer an NL or NL-OP function with the 8827 exit device?
Resolution:
This option is not available as there is no NL cam to directly drive the rods and using a key to lift the heavy stainless, brass or bronze rods would damage the key. :
Can a 24-R, 24-V, 25-R, or 25-V device use just a cylinder on the pull side for NL-OP function?
Resolution:
This is possible. A rim cylinder with cylinder anchor plate is used (anchor plate provided with rim cylinder package). No other special components are required. Order device as NL-OP.&...:
Do I have to use the 388 to get NL-OP on a 33A/35A series device?
Resolution:
The 388 Cylinder Control is required for the NL-OP function on a 33A/35A series exit devices.The 110NL is used on 22 and 98/99 series exit devices not 33/35A series devices.The 33A/35A de...:
Does Von Duprin supply the 9875, 9975, 9875-F and 9975-F mortise exit devices with NL-OP trim function?
Resolution:
For night latch function with pull by others, the 98/99 series mortise exit device should be ordered as NL less trim, e.g., 9875NL-L/TRIM. We will furnish a device only, and the mortise cyl...: