ND-series timing guide

RELATED FAQS

Question
Answer
Incorrect timing of the lock can cause the outside lever to retract the latch when raised up.  See instructions here (Step 16 and 17) to time a T351, T381, T561, and T571.  Also applies to the same...
To verify the timing on a T561, function test the outside lever after locking it.  To lock the key should only rotate 180 degrees (Not 360 degrees as Schlage does) A properly timed lock will n...
Schlage offers the 10-042 Electric strike, 1 1/4" x 4 7/8", 606 and 626 finish only. Related solution: What are the current and voltage requirements of the 10-042 strike?
Medeco does offer a key-in-lever cylinder to fit the Schlage ND.You will need to contact Medeco for the cylinderSpecify a key-in-lever cylinder to fit the Schlage ND lock.They will supply a cylinde...
Order the M204-198 thru-bolt jig, see Figure 1. Figure 1: M204-198 thru bolt jig The 40-080 was the old Schlage jig. The 030736-000-70 was the old Falcon jig.  When the jig changed to...
SCHLAGE locks are available with the following backsets: Lock Series Lock Type                 ...
The ND40 does not have this option.  You will need to look at a mortise lock, L9496, or a deadbolt such as the B571.
The ND-Series FSIC driver is part number N523-127.
As of February 2016, ND locks began shipping with a new latchbolt. The new latchbolt offers substantially improved performance in adverse door conditions (ex, with heavy door loading) andis more ro...
Prior to February 2016, using ND-Series locks on hollow metal doors required the use of latch spacers which prevent the latch from "fishtailing" (back end of latch moving from side to side). Latch ...
Only the Schlage D-knob and ND products are available with an extra long backset.  The part number for backsets over 5"-42" is XC03-069, this part will ship as an extension link to be used with a s...
On ND locks manufactured on or after January 30, 2017 only the SFIC lever and SFIC driver are needed to convert the lock from Full Size conventional (PD) or Full Size IC (JD, RD, TD) prep to S...
On ND locks manufactured prior to January 30, 2017, the lever, spring cage and tailpiece needed to be replaced with the SFIC lever, SFIC spring cage and the SFIC driver . N123-056 - Outside sp...
There are several part numbers available: Part Number Contents 09-774 SFIC driver & Spacer N523-091 SFIC driver D500-000 Spacer
Warranty Statement3 Year Limited Mechanical Warranty and 1-Year Limited Electromechanical Warranty - Additional warranties listed below The provisions of these limited warranties do not apply to P...
ND locks shipping on or after January 30, 2017 no longer require the use of the soft durometer spacer. Lever installation on the redesigned ND locks should not be difficult.
For ND locks shipping prior to January 30, 2017, the addition of the soft durometer spacer (SDS) on August 15, 2012 did affect the installation of the lever.  Ultimately, removing th...
ND53PD (ANSI F109) Entrance Lock  Turn/push-button locking; pushing and turning button locks outside lever, requiring use of key until button is manually unlocked. Push-button locking; pushing bu...