On ND locks manufactured on or after January 30, 2017 only the SFIC lever and SFIC driver are needed to convert the lock from Full Size conventional (PD) or Full Size IC (JD, RD, TD) prep to S...
On ND locks manufactured prior to January 30, 2017, the lever, spring cage and tailpiece needed to be replaced with the SFIC lever, SFIC spring cage and the SFIC driver . N123-056 - Outside sp...
The letters GD, HD, BD, or BDC should be put after the lock function. EXAMPLE: ND53BD
GD = Schlage SFIC core
HD = Construction core
BD = Less core
BDC = Plastic temporary construction core
The ND12 and ND25 are both exit locks.ND12 Outside lever always fixed. Insidelever always unlocked for immediateegress.ND25Blank plate outside. Inside leveralways unlocked for immediate egress.
ND-Series Cylinder Reference Table
Function
Door Thickness
Cylinder Mechanism
Complete Cylinder
Non-Hotel Functions
Standard
Conventional
23-065
Primus
20-765
Pri...
As of August 26, 2013, the ND75/95 in 626 finish comes standard (no additional charge) with indicator rose with black lettering and indicator arrow.For locks that shipped prior to August 26, 2013, ...
Component
Function
Product
How to Order
Rhodes Indicator Rose
Classroom Security
ND75, ND95
XN12-035 (626 only)
Omega Indicat...
See attached bulletin. Marketing bulletin with associated Von Duprin indicators listed.