Why would a 4600 not open a full 90 degrees?
Resolution:
A 4600 (4630/4640) not opening to a full 90 degrees could be caused by a couple things: The Opening Force could be set too low. Try increasing the opening force adjustment on the controller a 1/...:
MOTOR CLUTCH
Resolution:
4600 Series, Power Operator:
I get three green blinks of the Schlage key and it says motor stall on my SUS/HHD during diagnostics?
Resolution:
Just align the triangles per the installation instructions to allow full motor movement. - This will eliminate the SUS motor STALL report. - This will eliminate the three ...:
What would cause a 4600 (4630/4640) to keep blowing fuses as soon as the 120VAC cable is plugged into control box?
Resolution:
The main AC fuse would blow if there is a direct short across the AC line. This could be caused by a:1. Defective I/O PC Board (-3180) To check - unplug the control box AC power cable (2 wire) fro...:
4600 with EO3, how to troubleshoot and how can you check the clutch and motor on a 4600 operator?
Resolution:
If you get an EO3 on the control box on a 4600 operator. E03 = Motor / Clutch not plugged in or open coil. To troubleshoot follow these steps:Verify that the motor is plugged into the c...: