MINIMUM STILE FOR FALCON LOCKS

RELATED FAQS

Question
Answer
The minimum stile for each lock will depend on the backset and the rose diameter/escutcheon width.  See the Schlage Minimum Stile Guidelines  for the minimum stile for each...
Depending on the door construction the minimum stile may differ but a safe dimension would be 4-3/4".  CUSTOMER must check door construction. The pocket depth requirements of the case is 4 1/2".
The minimum recommended Stile measurement is 5” to allow proper mounting of the AD and CO series locks.
The minimum stile and rail dimensions with glass trim are as follow: Top Rail: 6 1/4" top of door to exposed glass or 5 1/2" top of door to cutout Center Rail: 6 1/2" exposed gla...
55 and 88 are both crossbar exit devices.  55 Series is used on narrow stile applications, 88 is for wider stile applications. See attached tables for 55 and 88 series minimum stile requirement...
Minimum dimensions to cutouts for glass lights: Vertical edge of door to edge of cutout = 5 29/32" Top of door to top of cutout = 6" Bottom of door to bottom of cutout = 10" Reinforcing chann...