Question
Answer
The Minimum single door opening should be 26.32" and use the 299 or 499F strike.
Minimum door opening for a 98/99 rim device with a 4954 mullion and 299 strike is  26.687" (26 11/16")
The use of Panic Hardware and/or Fire Exit Hardware is required by the International Building Code (IBC) and NFPA 101 – The Life Safety Code, depending on which code and which edition of the code i...
The minimum stile for each lock will depend on the backset and the rose diameter/escutcheon width.  See the Schlage Minimum Stile Guidelines  for the minimum stile for each...
"PUSH SIDE" application: Minimum 52" wide pair, with neither door being less than 21" wide. "PULL SIDE" application: Minimum 60" wide pair, with neither door being less than 30" wide.
The minimum door opening width (for mounting a pair of 4640 or 4630 operators on a double door) is 72" wide (2 - 36" door leaves). Mounting the 4640 or 4630 on a double door that is less than 72" w...
The minimum clear opening width for ADA is 32" measured from face of door opened to 90 degrees to face of stop on strike jamb. There must be no hardware mounted to the door projectin...
The minimum door widths for mounting a Senior Swing are: Concealed 2810 Series: 2811 single door (offset pivot or butt hinge) -- 33". 2811 single door with stop (center pivot) -- 36". 2853 pa...
Yes, glass light can be used or prepped in conjunction with the Von Duprin 94/95 Series INPACT device however there are dimensional limitations between the glass light and the InPact door preparati...
Glass lights available: Standard Glass Lights - The N4, N5 & V lite can be used at standard locations with out any modification. Glass Light Options - Other glass lights are available but ...
Panic Hardware and Fire Exit Hardware are two different types of exit devices, and the proper selection is determined by code requirements. Panic Hardware is an exit device which is tested for u...
The most obvious difference (in the device) is the lack of mechanical dogging on a Fire Rated Device.  There are some internal parts that may be different and the method it is secured to the d...