minimum door width for closer

RELATED FAQS

Question
Answer
"PUSH SIDE" application: Minimum 52" wide pair, with neither door being less than 21" wide. "PULL SIDE" application: Minimum 60" wide pair, with neither door being less than 30" wide.
The minimum stile for each lock will depend on the backset and the rose diameter/escutcheon width.  See the Schlage Minimum Stile Guidelines  for the minimum stile for each...
The Minimum single door opening should be 26.32" and use the 299 or 499F strike.
Minimum door opening for a 98/99 rim device with a 4954 mullion and 299 strike is  26.687" (26 11/16")
The minimum door opening width (for mounting a pair of 4640 or 4630 operators on a double door) is 72" wide (2 - 36" door leaves). Mounting the 4640 or 4630 on a double door that is less than 72" w...
The minimum clear opening width for ADA is 32" measured from face of door opened to 90 degrees to face of stop on strike jamb. There must be no hardware mounted to the door projectin...
The minimum door widths for mounting a Senior Swing are: Concealed 2810 Series: 2811 single door (offset pivot or butt hinge) -- 33". 2811 single door with stop (center pivot) -- 36". 2853 pa...
When templated for 140° the 4010 will fit on a 16-1/2" door leaf MINIMUM.
Clear Opening Width for swinging doors is measured (with the door open 90 degree) from the face of door to stop soffit on strike jamb.          &nbs...
Overhead Concealed door closers are used to provide a more aesthetic look to the opening.  Concealed in either the frame or the door Offer the ability to be adjusted to maintain control o...