minimum door leaf width for auto operator unequal pair
”
RELATED FAQS
Question
Answer
Can a Senior Swing 9550 be mounted on an unequal pair of doors?
Resolution:
"PUSH SIDE" application: Minimum 52" wide pair, with neither door being less than 21" wide. "PULL SIDE" application - For Product Shipped...:
Can an auto operator be installed on a Dutch door?
Resolution:
Yes, an automatic operator can be installed on a Dutch door. The operator must be installed on the top leaf of the Dutch door. Only the top half will open unless the top and bottom leaves (se...:
How do you install a Senior Swing 9540 on one leaf of a double door?
Resolution:
Surface Mounting - A 9542 HDR2 (Double Door Header) and a 9540-18 mounting plate can be used on the active leaf. A manual closer with a PA (parallel arm) can then be installed on the inactive leaf....:
What are Pneumatic Automatic Operators?
Resolution:
Pneumatic Automatic Operators are used in areas where electrically operated devices are not convenient or permitted. Consists of a modified, heavy-duty door closer for manual oper...:
What are the minimum header lengths for a Senior Swing?
Resolution:
The minimum header lengths for a Senior Swing are: Concealed 2810 Series: 2811 single door (offset pivot or butt hinge) -- 33". 2811 single door with stop (center pivot...:
What is the minimum door opening width for mounting the 4640 or 4630 on a double door?
Resolution:
The minimum door opening width (for mounting a pair of 4640 or 4630 operators on a double door) is 72" wide (2 - 36" door leaves). Mounting the 4640 or 4630 on a double door that is less than 72" w...:
What power supply do I need for my 2 QELA devices with LCN auto operator?
Resolution:
Use the PS902-2RS power supply with LCN auto operator on single door, PS904-2RS power supply on double door and PS904/906-2RS-2RS for 2 pair of QELA is required for basic operation with a...:
What is clear opening width?
Resolution:
Clear Opening Width for swinging doors is measured (with the door open 90 degree) from the face of door to stop soffit on strike jamb. &nbs...:
Why does the auto operator not open the door when installed with a Chexit?
Resolution:
Chexits are NOT electric latch retraction devices, therefore the latch will not retract and allow the opener to swing the door open. Chexits block and unblock the latch. In order for a Ch...:
How do you order a Senior Swing header for a 2810 on one leaf and a 2010 on the other?
Resolution:
LCN does offer a 2810 Senior Swing / 2010 manual closer combo for a pair of doors. Both units contained within the same Senior Swing header. To order a paired operator with a 2810 o...: