Make closure with more pressure
”
RELATED FAQS
Question
Answer
Does LCN sell a coupler to stack two 4040XP closers together?
Resolution:
LCN does not recommend this type of installation, and has never sold a coupler to do this.:
What door meets FBC / NOA Zone 4 requirements?
Resolution:
H-Series doors in single leaf applications with only mortise locks meet the FBC / NOA Zone 4 requirements?3070 max flushOutswing & Inswing applicationsZone 4 requires 120 to 170 psf.:
What is power boost on a Senior Swing or Benchmark operator?
Resolution:
Power Boost is a positive latching feature that increases the latch force, to over come building stack pressure or door weather stripping, etc, if the door stops before co...:
What is UBC 7-2?
Resolution:
The UBC (Uniform Building Code) was a regional legacy building code which was superseded in most jurisdictions by the IBC (International Building Code). There may be some areas of the country which...:
How do I get a Size 1 (ADA) closer to close against air pressure?
Resolution:
If an Size 1 (ADA) closer is set to 5 lbs. opening force, it will only have about 3 lbs. (60/70%) closing force. If the closer will not close against air pressure, but the ADA requirements have to ...:
What can be done for a door that will not close against wind pressure?
Resolution:
To correctly answer this question, we need to know how much more force is required to get the door closed. They could try turning the Rod & Shoe over (short side of shoe towards the hinge), or they...:
What is the minimum and maximum PSI applied to a 4800 operator?
Resolution:
The pneumatic operators are designed to function with an input air pressure to the 7901/7902 Series control box of 80 (min) 100 (max) PSI, and an output pressure of 60 to 80 PSI to the pneumatic (2...: