Will the Von Duprin 6210 electric strike operate with the MA series locks?
Resolution:
The Von Duprin 6210 electric strike was designed for retrofit applications and will not work with the Falcon MA series lock when strike and lock body are mounted at standard locations (centerline o...:
Are the M and MA locks compatible?
Resolution:
No parts are compatible between the Falcon MA-Series and the obsolete Falcon M-Series.:
What is dual switch monitoring or DS?
Resolution:
The DS is Dual Monitor Switch for Von Duprin 6100 and 6200 series electric strikes (not 6300 or 6400)DS option cannot be added to a Von Duprin 6000 series electric strikes in the field. It is only ...:
Why won't the 5100 24v strike work on both a RH & LH door?
Resolution:
The 5100 strike details are listed below: Only operates with 12VDC or 24VDC power supply. Will not operate with AC transformer. 12 or 24VAC can be converted to 12/24VDC using Von Duprin SO12 o...:
What is the amount of pre-load force allowed for the 6300 electric strike before the strike will no longer release and operate properly.
Resolution:
The 6000 series electric strikes 6100, 6200, 6300 models, require that there be no preload at all on the strike lip to function properly.:
Will the 6300 electric strike work with the 22 series rim device?
Resolution:
The 6300 surface mounted electric strike can be used with a 22 rim device.: