What height should a lock or deadbolt be installed?
Resolution:
According to ANSI specifications for cylindrical or mortise locks: The lock strike centerline should be 40 5/16" from the bottom of the frame with the lock in relation to the strike.&...:
Where is factory recommendation for location of an EPT?
Resolution:
EPT installation guidelines are as follows: Recommended location is 6" below top hinge per template Steelcraft will locate the power transfer prep at the Von Duprin re...:
Where is the EPT location of a Pin-and-Barrel Continuous HInge?
Resolution:
The 600/700 Series EPT Template shows recommended locations based on the standard sizes, The customer can provide a different dimension measured from the top of the hinge to the Cen...:
What is the minimum rose dimension that can be used with a Steelcraft 61L lock preparation?
Resolution:
The minimum rose that can be used on the 61L (ANSI/BHMA A156.115.18) preparation is 3 7/16".Steelcraft's 61L lock prep (often referred to as the "Squashed Turtle lock prep") is designed for Bored L...:
Does the door prep need to be altered when ordering the L9000 locks lead lined?
Resolution:
The door template L1 states: "Lead Lining: When L9000-Series or L400-Series locks are ordered with lead lining, add 1/8" to the width of the mortise cut-out on the lock case cover side of installa...: