less bottom rod height
”
RELATED FAQS
Question
Answer
Can you do LBR on a 98/9947 WDC?
Resolution:
This is available. If this is a fire rated opening you must use the Auxiliary Fire Latch Kit to maintain your Fire Rating. If not fire rated simply omit the bottom rod but be aware that your...:
Is the 2227 panic exit device available LBR?
Resolution:
The Von Duprin 2227 or 2227-F exit device is available less bottom rod. Specify 2227-LBR or 2227F-LBR for fire.:
Is the 8827 available LBR?
Resolution:
Von Duprin offers a PL8827 LBR device with a pullman style top latch and Less Bottom Rod for use with electric strikes, but is not UL labeled nor ANSI/BHMA certified.:
Can you order 8827L-F less bottom rods?
Resolution:
Von Duprin will not supply the 8827-F less the bottom rod because the device has never been UL tested less bottom rod.:
Where do I install my Auxiliary Fire Latch (AFL) in a Less Bottom Rod, Fire Rated (LBR-F) exit device?
Resolution:
Installation should be 6" from bottom of the door. See attached templates as reference. T-5494 for HM Doors W-5494 for Wood Doors:
Can the electric strike be used with a vertical rod device on a fire-rated door?
Resolution:
Not for use in fire rated openings.: