Lead lined latch

RELATED FAQS

Question
Answer
The ND lead lined option is specified by XN12-307 and consists of two 1/16” thick rose plates, a single 1/8” button/cylinder plate and a 1/16” latch sleeve.
Lead lining is not needed, since the channel or through bolt is solid and the x-rays will not penetrate the solid metal.
The door template L1 states: "Lead Lining: When L9000-Series or L400-Series locks are ordered with lead lining, add 1/8" to the width of the mortise cut-out on the lock case cover side of installa...
Not specifically for lead lined doors.  But the standard hinges should work and not hit the lead lining in the door.  Since standard lead layers vary, check with door manufacturer an...
Lead lined frames are intended for use in the X-ray Room locations in Health Care facilities. Frames are provided by Steelcraft prepped as follows:  Frames are supplied knock-down (KD). Fram...