Lead lined frames are intended for use in the X-ray Room locations in Health Care facilities. Frames are provided by Steelcraft prepped as follows:  Frames are supplied knock-down (KD). Fram...
Ives does not offer a continuous hinge designed specifically for lead lined doors.  Standard hinges may work if the hinge and mounting hardware do not penetrate the lead lining in the door.&nb...
Ives does not offer any lead lined pivots.  An appropriate model of pivot would be determined by the weight of the door and where the lead lining is in the door.  Because ...
The door template L1 states: "Lead Lining: When L9000-Series or L400-Series locks are ordered with lead lining, add 1/8" to the width of the mortise cut-out on the lock case cover side of installa...
Radiation, Lead Lined
Yes, an automatic operator can be installed on a Dutch door. The operator must be installed on the top leaf of the Dutch door. Only the top half will open unless the top and bottom leaves (se...
Standard Doors: standard inverted bottom channels will accept the following manufactures automatic door bottoms: National Guard (320) Pemko (420) Zero International (355/354)