lead lined auto flush bolt

RELATED FAQS

Question
Answer
Ives does not offer a continuous hinge designed specifically for lead lined doors.  Standard hinges may work if the hinge and mounting hardware do not penetrate the lead lining in the door.&nb...
Lead lining is not needed, since the channel or through bolt is solid and the x-rays will not penetrate the solid metal.
The door template L1 states: "Lead Lining: When L9000-Series or L400-Series locks are ordered with lead lining, add 1/8" to the width of the mortise cut-out on the lock case cover side of installa...
Ives does not offer any lead lined pivots.  Some of the Ives pivots can be used on lead lined doors such as the 7230F, 7237F, 7230F/7237F Int.  The hole pattern for the mounting screws are offs...
Lead lined frames are intended for use in the X-ray Room locations in Health Care facilities. Frames are provided by Steelcraft prepped as follows:  Frames are supplied knock-down (KD). Fram...