Question
Answer
Where do I install my Auxiliary Fire Latch (AFL) in a Less Bottom Rod, Fire Rated (LBR-F) exit device?
Resolution:
Installation should be 6" from bottom of the door. See attached templates as reference. T-5494 for HM Doors W-5494 for Wood Doors:
What is AFL on fire rated LBR exit devices?
Resolution:
AFL stands for "Auxiliary Fire Latch" on fire rated exit devices.:
Is the 8827 available LBR?
Resolution:
Von Duprin offers a PL8827 LBR device with a pullman style top latch and Less Bottom Rod for use with electric strikes, but is not UL labeled nor ANSI/BHMA certified.:
Does Von Duprin have a fire latch that will go into the floor?
Resolution:
Auxiliary fire latch is tested only from door to door latching by Von Duprin. Some door manufacturers have tested our devices LBR and use additional fire latches to pass the fire test. Contact the ...: