Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
LATCH INACTIVE LEAF STORAGE ROOM
”
RELATED FAQS
Question
Answer
Can an 18-R-L be converted to L-NL function in the field?
Resolution:
Follow step 6 of the 18-R instructions to convert trim function to Night Latch(L-NL).:
How do I change the function of the Von Duprin 7500 mortise lock from Lever ( classroom ) to NL ( night latch )?
Resolution:
To convert the Von Duprin 9975L to 9975NL exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory): Turn the NL screw on 7500 mortise lock counter clo...:
What is the difference between Night Latch (NL) and Class Room function?
Resolution:
Night Latch (NL)= key retracts the latch momentarily to allow entry. When key is removed, the latch will extend and locks the door (momentary unlock). Class Room (Lock/ Unlock)= key unlocks...:
Are flush bolts available on the inactive leaf of hurricane double doors with either FBC or NOA approvals?
Resolution:
Ives SB360 surface bolt at top and bottom are the only flush bolts approved for use on H-Series hurricane FBC or NOA applications? The only approved latching hardware for inactive leaf of pairs w...:
What electric strike can be used on a pair of doors with an L9000 lock?
Resolution:
Von Duprin 6223 electric strike is the most common closed back strike or the 6221 for open back strike on inactive leaf that can be used with Schlage L9000 or Von Duprin 7500 mortise lock.:
Does Schlage make a mortise lock that the lever on either side retracts the latch and a key on either side retracts the deadbolt?
Resolution:
The L9466 Store/Utility Room lock can provide this functionality. Operation: Latchbolt retracted by knob/lever either side. Deadbolt thrown or retracted by key from either side. When the deadbolt ...:
My COR is not allowing my inactive leaf with push side overlapping astragal to close first.
Resolution:
Astragal must be applied to pull side of active leaf, since placing the stragal on the inside of the inactive leaf will interfere with the active door closing.:
What strike do I use with a Von Duprin rim device on a pair of doors with flush bolts?
Resolution:
NON Fire Rated doors would use the 1609 strike applied to the inactive leaf with flushbolts. This may NOT be used on Fire Rated openings.:
INACTIVE LEAF
Resolution:
Inactive Door, Wde Inactive: