Question
Answer
Is there a Fire-Rated 33A Rim device?
Resolution:
The Von Duprin 33A/35A rim narrow style exit device is only for non rated openings and fire rating is not available with this device. The Falcon F24-R is a narrow style fire rated exit device T...:
Can a 3 hour A labeled Fire Door be prepped for multiple glass lights?
Resolution:
A fire rated door for 3 hours can have one glass light maximum: 100 square inches and must have an approved glass (Firelite type) Max glass size cannot exceed 12" in width or 33" in height. Wi...:
LABELED FRAME
Resolution:
UL, WH, FM:
LABELED DOOR
Resolution:
Conforms to all applicable codes, governing fire rated doors and bears label:
FIRE LABELED
Resolution:
ULA or 3 hour or 180 min., ULB or 1 1/2 hour or 90 min, ULC or 3/4 hour or 45 min, ULD, ULE, WH3, WH1 1/2, 20 MINUTE; UL, WH, FM:
How many P & D (Pierce and Dimple) holes are in a frame?
Resolution:
The following are quantities of EMA anchors (pierce and dimples) based on range of frame height: Quantity Nominal Frame Height 2 1'...:
What doors are available with monorail preps?
Resolution:
Monorail cutouts are only available for non fire rated applications.:
How do I manually program the AD300 RS-485 Address?
Resolution:
Manually Setting the RS-485 Address This method is only available before the first network communication between an Access Control Panel (ACP) and the lock. Do a Level 1 and Level 2 Factory De...: