l series rx wiring

RELATED FAQS

Question
Answer
The ND lock is available with an RX option:When ordering a complete ND lock specify RX when the request to exit (RX) switch is required.The ND80EL, ND80EU, ND96EL, ND96EU, ND12EL, ND12EU electrifie...
RX wiring on all L9000 locks with RX switch manufactured after January 2, 2017:The L-Series switched to a handed modular three-wire request to exit (RX) switch. This change was originally completed...
Specific to the RX switch installed into the L9080EL/EU and L9082EL/EU and L9000 mechanical locks prior to January 2, 2017:ALL PART NUMBERS BELOW DISCONTINUEDThe L-Series switched to a three-wire r...
The ND-Series RX,  the L-Series RX and latch monitoring switches are Form C - Single Pole Double Throw (also known as SPDT).
Supply wires - 22AWG
RX wires - 22AWG
LX wires - 22 AWG
You must replace the entire RX switch assembly for Chexit devices shipped after 8-24-2015 with motor driven.
The part number for the RX switch pig tail (black plug) with two orange wires only for Chexit devices shipped prior to 8-24-2015 with solenoid driven is 991338-00. 
The hole should be drilled in the field once the end cap is located on the door.  It is a 5/8" hole, that is located 5/16" from the end of the mechanism case. See installation instruction of t...
For the older 17/18 or current 19 device per instructions :  Red - Normally Open  Green - Common   Black - Normally Closed
For 24/25 devices per instructions :   Violet - Normally Open   Black - Common   Gray - Normally Closed