is ND series available lead lined

RELATED FAQS

Question
Answer
Ives does not offer any lead lined pivots.  Some of the Ives pivots can be used on lead lined doors such as the 7230F, 7237F, 7230F/7237F Int.  The hole pattern for the mounting screws are offs...
The ND lead lined option is specified by XN12-307 and consists of two 1/16” thick rose plates, a single 1/8” button/cylinder plate and a 1/16” latch sleeve.
XL11-515 is an option for lead lining on the L9000 series mortise locks. XL12-216 is an option for lead lining on the L400 mortise locks.
The door template L1 states: "Lead Lining: When L9000-Series or L400-Series locks are ordered with lead lining, add 1/8" to the width of the mortise cut-out on the lock case cover side of installa...
Lead lining is not needed, since the channel or through bolt is solid and the x-rays will not penetrate the solid metal.
Not specifically for lead lined doors.  But the standard hinges should work and not hit the lead lining in the door.  Since standard lead layers vary, check with door manufacturer an...
The determination was made that Lead Lined covers are no longer needed for the LCN product line, see below Marketing/EHS document. Lead Lined cover discontinuation letter
Lead lined frames are intended for use in the X-ray Room locations in Health Care facilities. Frames are provided by Steelcraft prepped as follows:  Frames are supplied knock-down (KD). Fram...