The Fusible Link arm is available with the 4010, 4020 and 4110 series closers. They all use the same Fusible Link arm. The UL Listing number is for the Fusible Link arms is R1943. The 4010 Serie...
ST-1630 is required when mounting a 4041 or 4040XP door closer regular (pull/hinge) side with a concealed GJ100 or GJ410 series over head stop.
FL, hold open arm
It would be unnecessary to use the CNS/Cush arm and the Glynn Johnson overhead devices in the same application, both mechanisms stop the door.
ST Number Product 1 Product 2 Description ST-2776 4040XP Rw/62A Overhead stop 81, 90, 100, 410, 450 series The standard P...
A 4040-18G drop plate will be needed to drop the closer and arm down far enough not to conflict with the GJ 90 series overhead stop.
Special template ST-2211 is used to mount a 2030 series closer with a GJ 70,79,81,90, and 450 series overhead stops. This ST works with any GJ "surface" mounted stop. The 2030 closer cannot b...
ST-2730 is used with a 4110 closer and GJ90 series (up to size 4).  ST-2730 includes a special template and special arm with a -62G shoe and bent forearm. If a drop plate is required, a 4010-18 d...
The 62A shoe is used when it is necessary to install the door closer (lower) down on the door so that it will operate under accessories such as overhead stops, coordinators, etc.