Question
Answer
Schlage offers the AL170 single dummy trim, but for applications where a double dummy is needed you can install two AL170 dummy trims back-to-back.  Each AL170 is shipped with a threaded rod (part ...
The Schlage AL-Series SFIC locks require one (1) small format spacer (D500-000) for 7-pin cores and two (2) small format spacers for 6-pin cores.  When these spacers are not ins...
Changing the plunger assembly on the AL-Series requires disassembling the chassis.  Refer to Plunger Assembly Instructions for guidance.
The lever may be missing the slot feature for the core locking lug.  Verify slot is in place.
You can not install the S lever onto an AL lock.  The AL and S lever trim is not compatible with each other.
To install a Schlage ND170 click here for the installation instructions.
 Von Duprin surface mounted 6300 electric strike paper template and installation instruction are provided with the electric strike. See attached 6300 Template & I...