install exit device

RELATED FAQS

Question
Answer
Installation should be 6" from bottom of the door. See attached templates as reference.  T-5494 for HM Doors W-5494 for Wood Doors
Position the 379L  trim and attach with countersunk screw into the bottom stud of the trim.  Position the 55 Rim device and attach with the device mounting screw through the head of th...
We have several blank trims listed in the price book to cover existing trim prep in door.  DEVICE EO TRIM   22  230EO  88  880EO   98/99  990EO or 996EO*  33A/35A Rim, 33/3...
SLM - special laminated material - blocking is put into the wood doors so there is material to mount the exit device using wood screws.
The top rod is required for proper operation.  The top latch controls both the top & bottom rods and without the top latch/rod the bottom latch would release when pushpad or trim was used but then ...
Von Duprin Exit Devices (33A/35A, 98/99, etc) are handled on a case by case basis regarding their ability to handle salt and chemical environments. Our powder coated finishes US28 (Anodized Alum...
Recommendation is to use mild soap with a damp cloth to clean an exit device.
The attached table shows the part numbers for LX-RX and LX-RX-LC switches field installed.
Calibration is an internal process of the QEL device when energized the 1st time.  The solenoid will pull and drop 3 times on a standard calibration.  Calibration can be forced by pr...
Von Duprin warrants that the product manufactured by it and delivered here under will be free of defects in material and workmanship for a period as follows: Exit devices and trim for 36 months...
The 909 strike is used in single and paired non-fire rated and single fire rated openings.  The 954 strike is used in fire rated paired openings.
The 1609 strike cannot be used with Von Duprin XP98/99 exit device.
Cylinder dogging (CD) and an RX switch can be ordered together with 33/35 or 98/99 series.
This can be done ONLY with non fire rated exit devices.
The Request for Exit (RX) is available on the 55 and 88 Series Von Duprin devices.The RX switch is installed in the end case of 55 and 88 series exit devices.There is no kit to field install the RX...