if you disable delay action can you re-enable it?

RELATED FAQS

Question
Answer
Regular LCN closers have "3" regulating valves for General Speed, Latch Speed, and Backcheck. If the LCN closer has "4" regulating valves, then the closer has the Delayed Action feature. De...
How to:  What are the steps to adjust a door closer?Facts: All LCN and FALCON door closers will have 3 regulating valves and a spring adjustment.  All closers with a "Delay" feature ...
AVB stands for Advanced Variable Backcheck. It is a cylinder option when ordering a 4111 closer (without an ST) that allows backcheck to start at about 45 degrees instead of the normal 75 degrees. ...
The 4040XP Series is not available with delayed action. When a delay cylinder is ordered, you will receive the standard 4041 cylinder, not the 4040XP cylinder.
The coin cell Nuisance Delay on CO200 and CO250 can be temporarily disabled using the Schlage Utility Software.
Once disabled via the SUS application, the CO lock will no longer delay the access for valid credentials.
If your CO lock began indicating a low coin cell (Nuisance Delay) after a door file has been downloaded, the coin cell is low and should be replaced. (CR2032)The coin cell Nuisance Delay will be "A...
The coin cell Nuisance Delay settings in the SUS application is not available until such time that a Door file is successfully downloaded to the lockset.
The coin cell is ignored when the lock sets are used with Manual Programming ONLY or while in Construction mode.
DEL, delay closing