As of Feb. 8th, 2016- LCN launched a new HO feature (block) for all track closers, which is not handed. Part # for the Hold Open clip (block) is 3130-3054 and it also requires the...
Hold Open Closers & Magnets (Fire/Life safety products) provide a wide range of solutions. Single or multi-point hold open closers
Utilize an electromechanical closer.
Hold the door o...
The ES Filter started to ship with these units (Senior Swing/Benchmark/Falcon) on 4/22/2013. The ES Filter kit will help eliminate line noise from an Electric Strike if used.
See ...
On the Senior Swing, if you have line noise from a strike the unit could go into an Error Code on the Control Box (Er13) and will not operate. Adding the ES Filter, which is a diode, will eli...
On the Benchmark and Falcon, if there is line noise from a strike then the unit will lose it's hold open time. Adding the ES Filter, which is a diode, will resolve this issue and the unit wil...
The 3130SE, 4040SE, and the 4040SEH use the same track. The 4040SEL track is longer.
The SE/SEH (-3038) track is 22-3/4" long. It functions as a single point hold open, and can be set to h...
The 4610/4620 series operators are obsolete. There is no replacement part for any electronic component (motor/clutch, controller, input/output PC boards) for the obsolete 4610/4620 operators.Essent...
If a door is being held open by the LCN SEM 7800/1900 magnet or any ME/SE Series Sentronic LCN closer, you can remotely release that door to close by ordering the following parts and wi...
To adjust the hold open time on a 4600 (4630/4640) operator:
Press the "MODE" button on the control box 1 time to get into programming mode. The "YELLOW" mode indicator LED next to "HOLD OPEN TI...
The Senior Swing has an optional (plug in) Off/Auto/Hold Open switch available. The 8310-806R (rocker switch), or 8310-806K (key switch). CANNOT use switch by others, requires a special (center - n...
Make sure that the hold open nut is not on upside down. The orientation of the hold open nut depends on the mounting.
On a Top Jamb "Push Side" mount, the hold open nut would poi...
No, LCN does not have an electronic hold open closer (SE/ME Series) that will provide a solid 180° hold open position.
The 3130SE has an adjustable hold open position from 85° to 110° maximum.
...
The 1460 Regular Arm part numbers are:
Regular Arm -- 1460-3077 or 1460-3077L for long arm (must specify finish).
Regular Arm with PA -- 1460-3077PA (must specify finish).
Regular Hold Open Ar...
To install a 4041/4040XP with Rw/PA or Hw/PA arm, you need a minimum of 5-3/8" top rail on the door, measured from the bottom of the stop. If the top rail is less than 5-3/8", you will need to use ...
The hold open position on a "REG" or "EDA" hold open arm is set with the door to a few degrees shy of the desired hold open point. To properly set, open the door 5° less then the desired hold open...
The holding force on an SE/ME Series door closer is approximately 35 lbs. and they can be manually pulled out of hold open with approximately 35 lbs of force.