HHD programming with legacy

RELATED FAQS

Question
Answer
Cable used to connect Hand Held Device (HHD) to CIP for programming legacy CM/CL/KC products
Yes, several HHD's can be used with a single lock, as long as the HHD's have the same Coupling Password as the lock.
The HHD coupling password is set during the lock initialization, coupling process.
When the coupling password is changed the value is stored in the HHD and once coupled to a lock, the Coupling Password is also loaded in the lock/device memory.
The Coupling Password is compared whenever an HHD is trying to adjust lock configuration settings or downloading door programming files.
The newer "programmable" RF transmitters/receivers will not work with the older "dip switch" transmitters/receivers. The frequency and coding are different.
Locknetics company supplied electro-magnetic locking devices, electronic smart locks, and electronic security components to access control dealers and lock smiths.  Ingersoll-Rand acquired ...
To clear the memory on a CT500 controller, deleting all programming and codes from the controller and resetting to factory defaults, perform the following procedure: 1.   ...
A replacement BNC cable has been found through the manufacturer, E-Z Hook.  This company makes electronic testing equipment, and this cable is believed to be a good working replacement fo...
This product is obsolete and is no longer available from Schlage Electronics.
Early versions (12/09 ) of the AD200 User Guide in many DEMO kits incorrectly state the Programming sequence to change the a programming code. It shows entering the new programming code o...
To program the 8310-865 receiver: Set the dip switches 1 to the "OFF" (pulse) position. Set the dip switches 2 to the "OFF" (0.5s) position. Momentarily press the " No Delay" or "Delay" ...
-         With the CIP NOT inserted and the Schlage Utility Software (SUS) running o   Enter the Master Programming PIN or Present Loc...
CIP Module (P512-112) used with HH-Serial Cable and Hand Held Device (HHD) for programming legacy CM/CL/KC products. Used only with BM-150 HHD
Cable used to connect Hand Held Device (HHD) for programming legacy CM/CL/KC products. Must have SUS 6.3.3 in HHD to support the HH-2PIN Serial cable.
No, the AD400 / WRI400/ WPR400 only work with the PIM 400-485 or PIM 400-TD2. The legacy WA locks / WRI / WPR2/ WSM only communicate with the legacy PIM-485 or PIM-TD2.
Microsoft Windows 8, 7, Vista, and XP: Home, Basic, and Starter versions are not compatible with Schlage Express. What versions of Microsoft Windows are compatible with Schlage Express v...
The coin cell Nuisance Delay on CO200 and CO250 can be temporarily disabled using the Schlage Utility Software.
Once disabled via the SUS application, the CO lock will no longer delay the access for valid credentials.
If your CO lock began indicating a low coin cell (Nuisance Delay) after a door file has been downloaded, the coin cell is low and should be replaced. (CR2032)The coin cell Nuisance Delay will be "A...
The coin cell Nuisance Delay settings in the SUS application is not available until such time that a Door file is successfully downloaded to the lockset.
The coin cell is ignored when the lock sets are used with Manual Programming ONLY or while in Construction mode.
Conversion chart listed here. 
The 15” cable is intended to allow the CT5000 to be installed near the door opening and bring the HHD USB programming port down to a reasonably accessible location for access programming and s...
Out of the Box, or after a Factory Default Reset, all AD locks can be used in a "Construction Mode".    At launch ...   The AD-Series locks would accept the first card credentia...
Update your device firmware to the latest version to fix this early design / feature update
Yes.  The AD-200 and CO-200 each can be managed through manual direct lock keypad programming or PC software programming using an HHD to transfer programming information to the lock....
Update your lockset using ADFwPkg 2.19.0 or higher.  This new firmware update resolves this programming error problem (E701) and the error will no longer be presented.
The following Legacy information is important to understand before cross referencing power supplies: PS-900 option boards will NOT install onto the legacy power supplies. This includes battery a...
Von Duprin PS914-4RL power supply replaces the PS873-4TD.
All Senior Swing models are heavy duty operators and have the Push-N-Go (PNG) feature.  This feature is a programmable function in the control module.  The PNG settings are: Off, On, or FD (fixed)...
The old 800 series power supplies and boards and the new 900 series power supplies and boards are not compatible with one another.
The PS900 power supplies will only accept the 900-XX option boards.
         
  The Legacy wall mounted readers are replaced as shown in the table below:  The MTMS15 and MTMSK15 did not have any prior models that it replaced.
Customers will need to use the Schlage Utility Software (SUS) on the HHD lock programming device to set the desired magnetic track to be read for access control, if not using default Track 2&n...
Beginning with Firmware Packages ADFwPkg 2.16.3 and COFwPkg 1.20.0 the PIN length can be manually changed for AD200 and CO200 locks as follows: 1. Press {programming code (default is 97531)} then ...
Creating a Master Construction Credential - From first power up or after clearing memory: Remove the CT5000 lid. Press and hold the Schlage button. Present a credential to the reader within ...
This method is only available before the first network communication between an Access Control Panel (ACP) and the lock. Do a Level 1 and Level 2 Factory Default Reset (FDR) to remove any previ...
Manually Setting the RS-485 Address This method is only available before the first network communication between an Access Control Panel (ACP) and the lock. Do a Level 1 and Level 2 Factory De...
The Hand Held device (HHD) should not be loaded with more than 100 door files at a time.  The Schlage Utility Software has difficulty managing larger numbers of door files.
For best Schlage Utility Software (SUS) and Hand Held Device (HHD) performance do not put more than 100 door files at a time ....
Null converter used to connect Hand Held Device (HHD) to WA Series Legacy PIM, using the HH-Serial Cable
When trying to program a CM lock, it may display an error code with a solid green light and 10 read flashes. This indicates the lock has already been programmed with computer software and manual pr...
The programming processes for Allegion devices can be both product and features specific.  Some products programming processes are electronic in nature, others are physical in nature. &nbs...