heda vs hw/pa

RELATED FAQS

Question
Answer
The 4041 Rw/PA and the Hw/PA have the same template.  The only difference is the arm. The 4041/4040XP Hw/PA, if mounted to the 180° template, will hold the door open at 180°. Rw/PA is Regular A...
To install a 4041/4040XP with Rw/PA or Hw/PA arm, you need a minimum of 5-3/8" top rail on the door, measured from the bottom of the stop. If the top rail is less than 5-3/8", you will need to use ...
Yes, as long as you stay with the like style arm.  Example: replace an RW/PA with HW/PA, replace an EDA with HEDA, or replace a CUSH with HCUSH.
The 4040XP, 1260/1261, 1460/1461, 4030/4031 closers have the tri-pack mounting option when ordered with an Rw/PA or Hw/PA designation.
When placing an order for a 4041/4040XP Rw/PA with hold open, it would be ordered as a 4041 /4040XP Hw/PA. For an existing Rw/PA requiring the addition of a hold open function, a hold open arm woul...
The 62A shoe is used when it is necessary to install the door closer (lower) down on the door so that it will operate under accessories such as overhead stops, coordinators, etc.
ST Number Product 1 Product 2 Description ST-2776 4040XP Rw/62A Overhead stop 81, 90, 100, 410, 450 series The standard P...
Optional closer reinforcements are located at 3" from hinge jamb to the beginning of the reinforcement plate. This applies to Regular Arm, Parallel Arm, Top Jamb. Regular Arm (RA) closer reinfor...
The 1461 Rw/PA requires a 4-3/8" minimum top rail on the door without the use of a drop plate.  If top rail is less than 4-3/8" a 1460-18PA drop plate will have to be used.
The Rw/PA arm is simply a regular arm that is packed with a 62PA (parallel arm) shoe, which will allow a (Tri-Pack) closer to be mounted in a regular, top jamb, or parallel arm application.