The 900-FA fire alarm board doesn't mount directly to the PS914 power supply. The 900-8F option board is required with fire alarm board. Fire alarm board plugs to the 900-8F and 900-8F plugs into...
In order to make the F-Series biometric HP 2000 hand reader compatible with the EN-200 Ethernet Module, you must: 1) change the prom to allow the Ethernet to communicate, 2) install ...
The TK400 kit contains an PIM400-TD2 and a WPR400-DT (Dummy Trim) and charger.
The WPR400-DT reader has no electronics it is an empty plastic shell.
Since the WPR400-DT does not have electronics ...
If a factory default reset (FDR) is absolutely needed, you MUST temporarily replace the credential reader with another reader that has a Schlage Button. This should be rarely if ever required.
T...
The link to the specific sheet can be found by clicking here: http://us.allegion.com/content/dam/allegion-us-2/web-documents-2/InstallInstructions/Von_Duprin_PS914_Power_Supply_Installation_I...
The Basic PS914 power supply will not accept a 900-FA fire alarm board.
900-8F option board is required with PS914 power supply to accept 900-FA fire alarm board (900-8F is an adaptor board for...
Product Ordered after 7/10/2012 - Product identified by label on QEL motor
You no longer need to use the 900-2Q option board (no longer available) with the PS900 power supplies to ...
Product Ordered before 7/10/2012 - Product identified by no label on QEL motor.
You must use the 900-2Q option board with the PS900 power supplies to operate the QEL devices. The attached ta...
If an access control system is not available to test the card output on a hand reader, this card emulation test can be done to verify the card format is correct. These steps will guide you in...
The older 871-2Q card that was used on PS873 power supply will not work with PS914 power supply.
You don't need to use the PS914 power supply with 900-2Q board, you can simply use the PS902 power ...