Question
Answer
What drop plate is used with a 4040 Rw/PA?
Resolution:
The 4040 Rw/PA can be mounted 3 different ways. The 4040-18 drop plate is used for the regular pull side mount. The 4040-18TJ drop plate is used for the top jamb push side mount. The 4040-18P...:
What strike do I use with a Von Duprin rim device on a pair of doors with flush bolts?
Resolution:
NON Fire Rated doors would use the 1609 strike applied to the inactive leaf with flushbolts. This may NOT be used on Fire Rated openings.:
Does Ives offer a 296G Flush Bolt?
Resolution:
The 296G is is not a model number but rather the UL listing number. This listing would be on many Ives Flush Bolts including; FB30 and FB40 series Automatic Flush Bolts FB50 and FB60 ...:
Are flush bolts available on the inactive leaf of hurricane double doors with either FBC or NOA approvals?
Resolution:
Ives SB360 surface bolt at top and bottom are the only flush bolts approved for use on H-Series hurricane FBC or NOA applications? The only approved latching hardware for inactive leaf of pairs w...:
What is the minimum and maximum door thickness for the AD and CO series locks?
Resolution:
The minimum door thickness that the AD or CO series lock will mount on is 1 3/8". Be advised that this will require additional spacers to be ordered separately to allow the lock to mount...: