flush bolt parts

RELATED FAQS

Question
Answer
NON Fire Rated doors would use the 1609 strike applied to the inactive leaf with flushbolts.  This may NOT be used on Fire Rated openings.
The 296G is is not a model number but rather the UL listing number.
The 9550 series Senior Swing WILL NOT work on a pair of doors with Electric Strike and auto flush bolts because you cannot sequence the door openings with a 9550 simultaneous pair operator.&...
Ives SB360 surface bolt at top and bottom are the only flush bolts approved for use on H-Series hurricane FBC or NOA applications? The only approved latching hardware for inactive leaf of pairs w...
When using 98/9927 with flush transom above: You will need to use a 260U strike for flush transom applications OR a 260U-F strike for 98/9927-F fire rated device.
050090 for bottom latch retrofit kit and 050091 for top latch retrofit kit.
The AL series latches are not adjustable.