Can the 9949 CVC be used on fire rated wood doors?
Resolution:
There are several door manufacturers that have achieved a 90 minute UL Fire listing as shown. Von Duprin CVC with Marshfield Wood Door: Von Duprin is pleased to announce that Marshfield ...:
Are masonry T anchor fire rated?
Resolution:
Masonry T anchor are approved for fire rated frames up to 3 hours. T Anchors are shipped lose for field installation. Anchor construction: The T portion and the strap do have minimum dim...:
Can 5100 electric strikebe used on fire rated door?
Resolution:
The Von Duprin 5100 electric strike is not for fire rated applications.:
Is the Von Duprin 6223 fire rated for pairs of wood doors?
Resolution:
The 6223-FSE electric strike is fire rated for pairs of wood doors, but check with wood door manufacturer to see if they have been approved for this application.:
Is the 2670 Guard X fire rated?
Resolution:
The Von Duprin 2670 Guard X is used only on non fire rated doors thus is not fire rated.: