Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
FALCON ELECTRIC LATCH
”
RELATED FAQS
Question
Answer
How do you test a Falcon 24 or 25 Series EL solenoid?
Resolution:
The resistance readings for a Falcon 24 or 25 Series EL solenoid should read;Green to Yellow = Pull Coil, should measure between 1 and 2 ohms of resistance. Green to Orange = Hold Coil, s...:
Will the Von Duprin 6210 electric strike operate with the MA series locks?
Resolution:
The Von Duprin 6210 electric strike was designed for retrofit applications and will not work with the Falcon MA series lock when strike and lock body are mounted at standard locations (centerline o...:
What are the Falcon T lock electrical requirements?
Resolution:
Prior to June 2011 the T lock only supported 24V and the electrical requirements were as follows: 0.185 amp @ 24VDC Wire Gage 22 AWG See wiring diagram here - (Previous 2 wire versi...:
Is a Von Duprin or Falcon EL device available in 12V?
Resolution:
Electric latch retraction, EL, devices are only available in 24VDC. (Note: The EL option for 24/25 series and related service parts have been discontinued as of 7/25/2022):